TM 5-3610-253-14
Turn off power.
q.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
r.
After the main motor has stopped, remove the manometer gage and
reinstall test fitting nut and ball.
s.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
13 mm Socket with 3/8 in. Drive
19 mm Deep Well Socket with 3/8 in. Drive
6 mm Hex Head Key Wrench
10 mm Combination Wrench
22 mm Combination Wrench
27 mm Combination Wrench
0-150 Bar Manometer Gage
a.
Remove front electronics enclosure cover.
b. Remove right pillar cover.
c.
Remove bolts and hydraulic system cover plate.
d. Remove nut and ball on test fitting on P2 side of control block.
e.
Install manometer gage onto test fitting.
f. Turn on power.
(1) Using operator key, unlock the safety lock.
5-628