TM 5-3610-253-14
e.
Rotate the handles so that limit switch labeled "A" is fully activated
by the cam (this step lowers knife carrier to lowest position).
f. Check that the maximum movement left in the activation of the switch is
.06 in. (1.5 mm). Loosen screws on the switch and adjust as necessary.
Reinstall limit switch cover.
g.
h.
through m.
Place operator key back into safety lock.
i.
5-40.59 Adjust
Clamp Proximity
Switch (b29).
MOS: 35E, Special Electronic Devices Repairer
PERSONNEL:
Two persons are required to perform this procedure.
TOOLS :
Flat Tip Screwdriver
10 mm Combination Wrench
Remove front electronics enclosure cover.
a.
b. Remove left side of plastic top cover.
Using operator key, unlock the safety lock.
c.
d. Turn on power.
(1) Turn main power switch to I position.
(2) Turn Star-Delta switch to Y position. After main motor has reached
full speed, turn the switch to
position.
(3) Press control power on switch.
e.
Move backgauge forward or backward as required until backgauge position
is displayed on the measurement display.
WARNING
Always keep clear of moving parts while performing this task. Serious
injury may occur.
5-632