TM 5-3610-253-14
d.
Remove nut and ball on test fitting on P1 side of control block.
e.
Install manometer gage onto test fitting.
Turn on power.
f.
(1) Using operator key, unlock the safety lock.
(2) Turn main power switch to I position.
(3) Turn Star-Delta switch to Y position. After main motor has reached
full speed, turn switch to
position.
(4) Press control power on switch.
Move the backgauge forward or backward as required until backgauge
g.
position is displayed on measurement display.
WARNING
Be sure personnel and foreign materials are clear of the cutting and
clamping area before pressing the cutting buttons. Death or serious
injury may occur.
h. Perform several cutting operations to bring hydraulic system up to
normal operating temperature.
i.
Set clamp pressure adjustment knob to 150.
WARNING
Always keep clear of moving parts while performing this task. Serious
injury may occur.
5-626