TM 5-3610-253-14
h. Press down on the clamp foot pedal several times to bring the
i.
Once the hydraulics are at a normal operating temperature, press down
and hold the clamp foot pedal.
WARNING
Always keep clear of movi ng parts while performing this task. Serious
injury may occur.
If the pressure on the gage
Check the pressure on the manometer gage.
j.
is 16 bar (227 psi), proceed to step m.
k.
If the pressure is above or below 16 bar (227 psi), it will be necessary
to adjust the safety pressure. This is done by removing the cap on the
safety pressure relief valve and loosening the locking nut. Using hex
head key wrench, rotate the stem in for more pressure and out for less
pressure.
Repeat steps j. and k. until proper pressure is obtained.
l.
m.
Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
After the main motor has stopped, remove the manometer gage and
n.
reinstall the test fitting nut and ball.
o.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
17 mm Combination Wrench
13 mm Combination Wrench
22 mm Combination Wrench
0-150 Bar Manometer Gage
Remove front electronics enclosure cover.
a.
b. Remove right pillar cover.
Remove bolts and hydraulic system cover plate.
c.
5-625