TM 5-3610-253-14
f. Move the clamp proximity switch up or down as necessary so that LED V5
on circuit board IAR comes on.
NOTE
Be sure not to lower the proximity switch on top of clamp.
Tighten mounting bolts.
g.
h. Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock the safety lock.
i.
Reinstall top cover on left side and secure with screws.
Reinstall front electronics enclosure cover.
j.
MOS: 35E, Special Electronic Devices Repairer
TOOLS: Metric Caliper
Flat Tip Screwdriver
Ream of art paper approximately 2 in. (5.1 cm) in height,
SUPPLIES:
8 in. (20.5 cm) in length and 11 in. (28.2 cm) in width
Remove front electronics enclosure cover.
a.
b. Locate the IAR board and place switch S2 in the metric mode and switch
S1 in the cm mode.
5-633