TM 5-3610-253-14
Adjust Gear Limit Switches (S22a and b).
MOS: 35E, Special Electronic Devices Repairer
TOOLS:
Flat Tip Screwdriver
Metric Feeler Gage (1.5 mm)
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a.
Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. Remove cover from the limit switches.
c.
through h. to ensure that knife is at highest position.
d. On limit switch labeled "B", check that the maximum movement left in the
activation of the switch is .06 in. (1.5 mm). Loosen screws on the
switch and adjust as necessary.
5-631