TM 5-3610-253-14
Table 5-9. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. CLAMP MOVES DOWN TOO SLOWLY DURING CUTTING - Cont
h. With maximum setting on clamp pressure adjust pedal, perform a cut
checking clamp pressure. Pressure should be 130 bar (1848 psi).
(a) If incorrect pressure(s) are observed, adjust clamp pressure
(b) If correct pressures cannot be obtained, replace control
5. DURING KNIFE CHANGING, CLAMP MOVES UPWARD AFTER BEING LOWERED WITH PEDAL.
Check control valve linkage for broken or disconnected parts.