TM 5-3610-253-14
Table 5-9. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. PAPER CUTTER POWER SWITCH ON, MAIN MOTOR STARTS, ALL OTHER FUNCTIONS
INOPERATIVE - Cont
Check for 120 V ac at output of circuit breakers.
Step 3.
(a) If voltage is incorrect, replace circuit breaker (paragraph
(b) If voltage is correct, proceed to step 4.
Step 4.
Check for 220 V ac at input taps.
(a) If voltage is correct, replace control transformer (paragraph
(b) If voltage is correct, proceed to step 5.
5-218