TM 5-3610-253-14
CAUTION
level or hydraulic cylinder
Be sure suction hose inlet extends below fluid
will move erratically.
Install new suction hose to cylinder and tighten clamp securely.
e.
5-20.5 Replace Hydraulic Pump.
MOS: 83FJ6, Reproduction Equipment Repairer
Flat Tip Screwdriver
TOOLS:
13 mm Socket 1/4 in. Drive
6 mm Socket 1/4 in. Drive
22 mm Combination Wrench
Fluid Evacuation Pump
Hydraulic Pump
SUPPLIES:
Gaskets
Copper Washers
Pail
Cleaning Solvent (Item 26, Appendix E)
Hydraulic Fluid (Item 12, Appendix E)
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a. Turn off power.
(1) Turn main power switch to O position.
(2) Using operator key, lock safety lock and keep key in your
b. Remove the main motor V-belt cover.
Remove side reservoir cover and gasket.
c.
NOTE
If the hydraulic fluid is to be reused, be sure that the pail is clean
before pumping fluid into it.
5-240