TM 5-3610-253-14
Table 5-9. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PAPER CUTTER POWER SWITCH ON, MAIN MOTOR STARTS, ALL OTHER FUNCTIONS
8.
INOPERATIVE - Cont
c.
Press reset buttons on three main circuit breakers.
(a) If circuit breakers repeatedly trip, use schematic diagram
and troubleshoot system for short circuits.
(b) If circuit breakers do not trip and malfunction persists,
proceed to step 2.
Step 2.
Check for 120 V ac at input of circuit breakers.
(a) If voltage is incorrect, replace main power switch (paragraph
(b) If voltage is correct, proceed to step 3.
5-217