TM 5-3610-253-14
d. To adjust side-to-side looseness, loosen locking nuts on side adjusting
screws and adjust screws until free and easy movement without play is
obtained.
Turn off power.
e.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
5-36.17 Adjust
Table Stop Bolts
and Limit
Switches.
MOS: 83FJ6, Reproduction Equipment Repairer
Two persons are required to perform this procedure.
PERSONNEL:
17 mm Combination Wrench
TOOLS:
Flat Tip Screwdriver
6 mm Hex Head Key Wrench
SUPPLIES: None
Turn on circuit breaker.
a.
b. Using operator key, unlock safety lock.
c.
Turn on power.
(1) Turn main power switch to I position.
(2) Turn Star-Delta switch to Y position. After main motor has reached
full speed, turn switch to
position.
(3) Press control power on switch.
5-451