TM 5-3610-253-14
Repair Table Lamp.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
5 mm Hex Head Key Wrench
10 mm Combination Wrench
Pliers
SUPPLIES: Toggle Switch
Capacitor
Butt Connectors
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
Turn off power.
a.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. To replace toggle switch, proceed as follows:
(1) Remove fluorescent lamp.
(2) Remove right side cable holddown.
(3) Remove retaining screws on switch mounting bracket and carefully
lower switch and mounting bracket.
(4) Remove bezel nut on switch and lift defective switch from mounting
bracket.
(5) Tag and disconnect wiring from defective switch.
5-444