TM 5-3610-253-14
Perform a cut and observe the reading on the manometer. If pressure is
i.
not 130 bar (1848 psi), adjust clamp pressure as follows:
(1) Remove front electronics enclosure cover and right pillar cover.
(2) To increase pressure, tighten the limit screw on the bottom of the
clamp pressure control. To decrease pressure, loosen the limit
screw.
(3) Repeat step i. until pressure is 130 bar (1848 psi).
Reinstall front electronics enclosure cover and right pillar cover.
j.
k. Turn main power switch to O position.
Remove manometer from bleed port.
l.
Reinstall bleed port cap onto bleed port.
m.
5-281