TM 5-3610-253-14
(7) Using a level, level the table with the support leg and add shims if
necessary between the table and the frame.
(8) Secure table to frame using al 1 screws.
(9) Remove hoist from table.
(10) Connect all electrical connectors to the proper connections in the
electronics enclosure.
(11) Install the left and right light barrier housings to front frame,
ensuring that the housing is square to the table and frame.
(12) Connect light barrier plug connectors.
(13) Install the right and left side tables and secure in place with bolts.
(14) Install the table sides to the backgauge table.
(15) Secure the backgauge table to the mounting frame.
(17) Remove rust protection film and dirt from around and on the sledge.
(18) Install the backgauge onto the sledge. Make sure that all concave
washers are fitted between the concave spacer and backgauge. This will give the
proper distance 3 mm (.12 in.) between the backgauge and the table.
5-13.3
Prepare the Paper Cutter for Use.
Clean the paper cutter as follows:
a.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous
to personnel and property. Avoid repeated and prolonged skin contact.
Wear solvent impermeable-gloves and eye/face protective equipment when using
solvent. Do not use near open flame or excessive heat. Flash point of
solvent is 100F to 138F (38C to 59C).
(1) Using P-D-680 cleaning solvent, clean all grease from the bed assembly
and surfaces including sides and front table.
5-93