TM 5-3610-253-14
WARNING
High voltages that are capable of causing death may be stored in capacitor
after power is removed. Be sure capacitor is discharged and reduced to
zero volts.
(1) Remove retaining nut on back of defective capacitor.
(2) Tag and disconnect wires from defective capacitor.
(3) Reconnect wires to new capacitor.
(4) Install new capacitor and secure with nut.