TM5-6675-326-14
6-6.2.24 Linear Measuring Probe Measurements Without the Calculator -
Continued
NOTE
l
If constant is one or greater, set decimal
s e l e c t o r t o 0 .
l
If constant is less than one, set decimal
s e l e c t o r a c c o r d i n g t o p l a c e o f f i r st
s i g n i f i c a n t d i g i t .
g.
Place linear measuring probe on line to be measured so that
p r i c k i n g p i n i s a t s t a r t i n g
h .
Press CLEAR button to clear
i .
Make measurement by tracing
measuring probe.
p o f n t .
a u t o - s c a l e r.
l e n g t h o f l i n e w i t h l i n e ar
j .
Press foot switch to activate ACCU and freeze count.
k .
Multiply number shown in auto-scaler LED display to obtain
l e n g t h o f l i n e i n f e e t.
NOTE
l
I f f i r s t s i g n i f i c a n t d i g i t o f C L i s i n o n es
column (one place to left of decimal point),
multiply auto-scaler LED display by 10.
l
I f f i r s t s i g n i f i c a n t d i g i t i s i n t e n s
column , multiply auto-scaler LED display by
100.
l
I f f i r s t s i g n i f i c a n t d i g i t i s t h r e e o r m o r e
p l a c e s t o l e f t o f d e c i m a l p o i n t , i n c r e a se
m u l t i p l i c a t i o n f a c t o r b y 1 0 f o r e a c h p o s i t i on
i t l i e s f u r t h e r t o t h e l e f t.
6-6.2.25 Point Counts With Point Counter Pen and Constants
a. Assemble QPS with point counter pen.
b.
Activate QPS:
(1) Plug point counter pen into POINT COUNT. input jack on
back panel of auto-scaler.
(2) Plug power transformer cable into POWER supply jack on
back panel of auto-scaler .
6-71