TM 5-3610-253-14
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: 9 mm Combination Wrench
19 mm Socket with 3/8 in. Drive
SUPPLIES: Spacer Foils
Turn on power.
a.
(1) Using operator key, unlock the safety lock.
(2) Turn main power switch to I position.
(3) Turn Star-Delta switch to Y position. After the main motor has
reached full speed, turn the switch to
position.
(4) Press the control power on switch.
b.
Move the backgauge forward or backward as required until backgauge
position is displayed on measurement display.
Pull out the clamp pressure adjustment knob.
c.
Using the clamp foot pedal, lower the clamp onto the table.
d.
WARNING
Always keep clear of moving parts while performing this task. Serious
injury may occur.
Be sure that the clamp is parallel to the table. If not, adjust
e.
eccentrics to make the clamp parallel.
5-642