TM 5-3610-253-14
m.
Turn on power.
(1) Using operator key, unlock the safety lock.
(2)
Turn main power switch to I position.
(3)
Turn Star-Delta switch to Y position. After main motor has reached
full speed, turn switch to
position.
(4) Press control power on switch.
Move the backgauge forward or backward as required until the backgauge
n.
position is displayed on the measurement display.
WARNING
Always keep clear of moving parts while performing this task. Serious
injury may occur.
o.
To increase the spring tension, turn the adjusting nut to the right.
This will increase the clamp return.
To decrease the spring tension, turn the adjusting nut to the left.
p.
This will slow down the clamp return and ease the downward action of
the clamp.
Perform several clamping operations with foot pedal. Repeat steps o.
q.
and p. until the clamp's downward and upward motions are smooth.
r.
Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: T-Handle Key (8 mm Hex Head Key)
Knife Carrying Handles
Knife Setting Gage
32 mm Open End Wrench (2)
41 mm Open End Wrench
SUPPLIES: Knife
Turn on circuit breaker.
a.
b. Using operator key, unlock safety lock.
5-436