TM 5-3610-253-14
5-36.9 Replace Clamp Foot Pedal.
MOS: 83FJ6, Reproduction Equipment Repairer
13 mm Combination Wrench
TOOLS:
5 mm Hex Head Key Wrench
Clamp Foot Pedal
SUPPLIES:
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a. Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. Remove rear electronics enclosure cover.
Remove retaining bolt and wedge on rear of clamp foot pedal, and then
c.
remove defective clamp foot pedal from the front side of the cutter.
Insert new clamp foot pedal from the front side, and secure with
d.
retaining bolt and wedge.
Reinstall rear electronics enclosure cover.
e.
f. Place operator key back into safety lock.
g.
5-433