TM 5-3610-253-14
(3) Remove false clamp by depressing both release pins with tips of the
knife carrying handles.
(4) Clean the false clamp and clamp.
(5) Reinstall false clamp in storage location under the table.
(6) Press clamp pressure adjustment knob in, then press clamp foot pedal to
lower clamp fully. Then release the clamp foot pedal to raise the clamp.
e. Check that knife is square with backgauge by performing backgauge angle
f. Adjust OCL by loosening locknuts and moving mounting rods in, out, and
around, until cutting line is bright and sharp.
g.
h. Check adjustment of false clamp switch (S6) by moving the backgauge fully
forward. Check that backgauge rakes come far enough up to intertwine with the rakes
of the clamp. Perform following steps if adjustment is required.
(1) Remove front electronics enclosure cover.
5-387