TM 5-3610-253-14
3. HYDRAULIC RESERVOIR Remove the front electronics enclosure cover and the right
pillar cover. Remove the hydraulic system cover plate. Using a fluid evacuation
pump, pump all hydraulic fluid out of hydraulic reservoir and into a 5 gallon pail.
liters (4.5 gals.) of hydraulic fluid (OHA) into the reservoir to bring the fluid
level to the top of the sight glass. Perform a complete bleed of the hydraulic
5-32. REPAIR PARTS, SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT
(TMDE); AND SUPPORT EQUIPMENT.
5-32.1 Common Tools and Equipment. For authorized common tools and equipment,
refer to the Modified Table of Organization and Equipment (MTOE) applicable to your
unit.
5-32.2 Special Tools: Test Measurement, and Diagnostic Equipment; and Support
Equipment. Special Tools, TMDE, and Support Equipment is listed in the applicable
repair parts and special tools list and in Appendix B of this manual.
5-32.3 Repair Parts. Repair parts are listed and illustrated in the repair parts
and special tools list, TM 5-3610-253-24P covering organizational maintenance for
this equipment.
5-33. SERVICE UPON
RECEIPT.
NOTE
Minimum of four persons are required to service the paper cutter.
a.
The following sequence of steps are used to unpack the crate.
NOTE
The frame is mounted on two skids. The table is secured between wooden
beams. Individual parts and accessories are packed in a wooden box.
(1) Lift the crate approximately 10 cm (4 in.) off the ground and place
wooden blocks under all four corners.
(2) Remove nuts on the top of the crate and lift off the lid.
5-380