TM 5-3610-253-14
KEY
TOTAL MAN-HR
INTERVAL
MAN-HR
2.5
A
w
0.5
LUBRICANT
REFILL CAPACITY
INTERVAL
Grease,
W - 20 hours
GAA
of operation.
(MIL-G-10924)
bearing
all points
As required
A - 1000 hours
HDO
Lubricating
of operation
(MIL-L-2104)
oil
Backgauge
1 pt
GO-90
Gear Oil,
(MIL-L-2105)
90 Wt
Main drive
0.6 liters (0.52 qts.)
gear
OHA
Hydraulic fluid
(MIL-H-5606)
petroleum base
Hydraulic
17 liters (4.5 gals.)
reservoir
NOTES
Every 20 hours of operation, all grease fittings are required
1. GREASE FITTINGS
to be greased (GAA). To grease, simply insert the grease gun onto fitting and pump
grease gun twice.
2. MAIN DRIVE GEAR
Remove drain plug and drain gear lubricant into a utility pail
and discard. Clean and reinstall plug. To refill, remove filler plug and fill with
0.6 liters (0.52 qts.) of gear oil (GO-90) to bring oil level to top of sight glass.
Reinstall fill plug.
5-379