TM 5-3610-253-14
Be sure that both ends
Reconnect clamp cylinder pipe to control valve.
u.
of the pipe are connected -tightly.
v.
w.
x.
Place hydraulic fluid back into reservoir.
y.
z.
Reinstall electronics enclosure frame and secure with four mounting
bolts.
Reinstall any loose wires back into wire box and reinstall wire box lid.
aa.
ab.
Tighten the return spring the same number of turns it took to loosen it,
as noted in step n.
ac.
5-20.9 Replace Control
Transformer.
MOS: 35E, Special Electronic Devices Repairer
10 mm Nut Driver
TOOLS:
Flat Tip Screwdriver
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a. Turn off power.
(1) Turn main power switch to O position.
(2) Using operator key, lock safety lock and keep key in your
b. Remove front electronics enclosure cover by turning mounting screws one-
half turn left.
5-250