TM 5-3610-253-14
Tag and disconnect wires from control transformer taps and remove dummy
c.
connectors.
Remove control transformer mounting bolts, ground wire, and defective
d.
transformer.
e.
Install new control transformer, ground wire, and secure with mounting
bolts.
CAUTION
Cover
Leave no taps open to air or damage to paper cutter may occur.
unused taps with dummy connectors.
f. Reconnect transformer wires and reinstall dummy connectors.
Reinstall front electronics enclosure cover.
g.
h. Turn on circuit breaker.
5-251