TM 5-3610-253-14
5-20.1 Check
Clearance Between Knife
and Clamp.
MOS: 83FJ6, Reproduction Equipment Repairer
PERSONNEL: Two persons are required to perform this procedure.
Flat Tip Screwdriver
TOOLS:
Knife Reset Handles
Knife Carrying Handles
Metric Feeler Gage (0.3 mm)
a.
Turn main power switch to O position.
b. Remove main motor V-belt cover.
c.
WARNING
Keep hands and feet clear of main motor and hydraulic pump V-belt.
Death or serious injury may occur from failure to do so.
d. Turn on power.
(1) Turn main power switch to I position.
(2) Press control power on switch.
e.
Place a pile of paper under the clamp.
5-231