TM 5-3610-253-14
h. Tighten locknut.
i.
Position the backgauge to 3/4 in.
NOTE
It may be necessary to move the backgauge back in order to adjust the
stop bolt.
Loosen locknut and adjust front stop bolt to proper setting.
j.
k. Repeat steps i. and j. until proper adjustment is obtained.
l. Tighten locknut.
NOTE
Adjust limit switches to the following specifications:
Backward limit switch (b13)
36-1/4 in.
Forward limit switch with false
3-1/2 in.
clamp installed (b8)
Forward limit switch without false
1 in.
clamp installed (b9)
m.
Move the backgauge either forward or backward (depending on what
switch you are adjusting) until it stops automatically. (Do not
manually position backgauge.)
n.
Note the position on the measurement display.
5-198