TM 5-3610-253-14
i.
If an overcut exists, loosen the adjusting bolts on the backgauge; if
an undercut exists, tighten the adjusting bolt.
Repeat steps d. through i. until problem is corrected.
j.
k. Turn off power.
(1) Turn main power switch to 0 position.
(2) Using operator key, lock the safety lock.
5-16.26 Adjust
Clamp Connecting Rod.
83FJ6, Reproduction Equipment Repairer
MOS:
Two persons are required to perform this procedure.
PERSONNEL:
TOOLS:
Flat Tip Screwdriver
10 mm Combination Wrench
46 mm Open End Wrench (2 ea)
6 in. Steel Machinist Rule
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a.
Turn off power.
(1) Turn main power switch to 0 position.
(2) Using operator key, lock safety lock and keep key in your
b. Remove rear electronics enclosure cover.
Remove wire box cover.
c.
d. Remove bolts securing wire box brackets to frame.
Take care that wires are not disconnected from motherboard. Lower box
e.
to allow access to turnbuckle.
5-201