TM 5-3610-253-14
f. Loosen turnbuckle locknuts.
g. Adjust turnbuckle so that both edges of the clamp are the same distance
from table top.
h. Tighten turnbuckle locknuts.
i.
Reinstall wire box brackets and cover.
Reinstall lower back cover panel.
j.
k. Place operator key back into safety lock.
5-16.27 Manually Move Knife Carrier.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
Reset Handles
Flat Tip Screwdrivers
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a.
Turn main power switch to 0 position.
5-202