TM 5-3610-253-14
(2) Remove ballast mounting bolts from back of HP circuit board.
(3) Tag and disconnect wires from defective ballast.
(4) Reconnect wires to new ballast.
(5) Install new ballast onto back of HP circuit board and secure with
mounting bolts.
(6) Reinstall left pillar cover.
(7) Place operator key back into safety lock.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS: 2.5 mm Hex Head Key Wrench
4 mm Hex Head Key Wrench
6 mm Hex Head Key Wrench
SUPPLIES: Ream of paper approximately 5 cm (2 in.) in height,
76.2 cm (30 in.) in length, and 40 cm (10 in.) in width
a. Turn on circuit breaker.
b. Using operator key, unlock safety lock.
5-193