TM 5-3610-253-14
5-16.9 Replace Backgauge Limit
Switches.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
No. 2 Cross Tip Screwdriver
SUPPLIES: Switch
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
Turn off power.
a.
(1) Turn main power switch to 0 position.
(2) Using operator key, lock safety lock and keep key in your
b. Remove oil drip pans under backgauge table.
c.
Remove screws on the cover of the defective switch and remove the cover.
d.
Tag and disconnect wires from defective switch.
e.
Remove retaining screws and defective switch.
f.
Install new switch and loosely secure with retaining screws.
Reconnect wiring.
g.
h.
Reinstall cover and secure with screws.
i.
Perform backgauge limit switch adjustment for new switch (paragraph
5-158