TM 5-3610-253-14
5-16.8 Replace Backguage Overload Relay.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
Turn off power.
a.
(1) Turn main power switch to 0 position.
(2) Using operator key, lock safety lock and keep key in your
NOTE
There is a rubber gasket between cover and housing. Gasket must be reused.
b. Remove two screws holding relay cover in place and remove cover and
gasket. Be careful not to damage gasket.
c. Tag and disconnect wiring.
5-156