TM 5-3610-253-14
Remove cover from junction box, tag and disconnect wires from motor.
c.
d. Loosen four mounting bolts and nuts, slide motor back, and disengage V-
belt from pulley.
e.
Remove bolt, washers, and pulley from end of motor shaft.
f. Remove mounting bolts and defective motor.
Place new motor in position and reinstall mounting bolts but do not
g.
tighten.
h. Reinstall motor pulley, washers, and bolt.
Place V-belt on motor pulley and pull against motor to tighten V-belt
i.
until it has 6 - 9 mm (1/4 - 3/8 in.) deflection when pressed. Tighten
mounting bolts.
Reconnect wires to new motor and reinstall junction box cover.
j.
k. Reinstall V-belt cover and secure with nuts.
l.
Place operator key back into safety lock.