TM 5-3610-253-14
Remove foot switch mounting screws.
b.
c.
Remove pivot screws to release treadle.
Loosen screws on cable clamp.
d.
e.
Remove screws and washers holding microswitch.
Pull microswitch until terminals are accessible.
f.
Tag and remove wires from defective microswitch.
g.
Connect wires to new microswitch.
h.
Install new microswitch and secure with washers and screws.
i.
Tighten cable clamp.
NOTE
Be sure that treadle spri ngs are seated properly.
k. Replace treadle and secure with pi vot screws.
Reinstall mounting screws.
l.
Plug in power cord.
m.
3-16.11 Remove/Install Paper Stitcher.
MOS: 83FJ6, Reproduction Equipment Repairer
PERSONNEL: Two persons are required to perform this procedure.
TOOLS: Socket Set, 1/2 in. Drive
Paper Stitcher
SUPPLIES:
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
Unplug power cord.
a.
b. Remove bulk wire reel.
3-67