TM 5-3610-253-14
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
Crimping/Stripping Tool
SUPPLIES: Power Switch
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
Unplug power cord.
a.
b. Remove retaining screws from cover plate on power switch and remove
data plate and cover plate.
c.
Remove 90 degree conduit elbow from top of switch box.
d. Remove screw from cable set on bottom of switch box.
e.
Remove screws and pull power switch away from box on stitcher until
slots beside wire connectors are accessible.
f. Tag and disconnect wires from defective switch.
Reconnect wire to new switch.
g.
3-58