TB 1-4920-443-35
AEDATS IV T64 ALIGNMENT WORKSHEET
(c) Temperature and Speed Limit Control Panel
1 Engine Oil inlet Temperature
P-801
Thumb wheel setting 300
Input
Calibrator
Limit Control Panel
Indicator lit
Temp F
+/- 3F
32 F
____________
____________
In limit
100 F
____________
____________
In limit
200 F
____________
____________
In limit
270 F
____________
____________
90% Alert
____________
300 F
____________
____________
100% Warning
____________
(d) Channel 12
P-802
Engine Oil out Temp
Input
Doric
AEDATS 4
+/- 2F
(Toil_out)
+/- 1F
32 F
____________
____________
100 F
____________
____________
200 F
____________
____________
300 F
____________
____________
Transducer: T20 Hardware Name: HL13
(e) Temperature and Speed Limit Control Panel (Refer to page 34 step 36)
1 Engine oil delta temperature T-53, P-802, P-801 jumper Thumb wheel setting 150
Input
Calibrator
Limit Control
Indicator lit
Temp F
Panel
+/- 3F
Ambient
____________
____________
90% Alert
____________
+135F
Ambient
____________
____________
100%
____________
+150F
Warning
Audible
____________
warning
(f) Channel 13
P-803
B/M1 (Spare)
Input
Doric
AEDATS 4
+/- 2F
(T21)
+/- 1F
32 F
____________
____________
70 F
____________
____________
100 F
____________
____________
120 F
____________
____________
Transducer: T2 Hardware Name: J01
208