TB 1-4920-443-35
AEDATS IV T64 ALIGNMENT WORKSHEET
(n) Dyno-lube delta temperature (Refer to page 35 step 38)
1 Calibrator J23 Jumper J20, Thumb wheel setting 80
Input
Calibrator
Limit Control Panel
AEDATS 4
Temp F
+/- 3F
(TDyn_FA)
+/- 3F
+/- 1F
32 F
____________
____________
100 F
____________
____________
200 F
____________
____________
300 F
____________
____________
ambient +74F
____________
____________
90% Alert
____________
Ambient +80F
____________
____________
100% Warning
____________
Audible warning
____________
Transducer: T64 Hardware Name: J24
(o) Channel 22
J21 Dyno rear bottom
Dyno lube out fwd
34)
Input
Doric
AEDATS 4
+/- 2F
(Tdyn_Fwd )
+/- 1F
32 F
____________
____________
100F
____________
____________
200 F
____________
____________
300 F
____________
____________
Transducer: T62 Hardware Name: J22
(p) Channel 23
J22 Dyno front bottom
Dyno lube out aft
Input
Doric
AEDATS 4
+/- 2F
(TDyn_Aft)
+/- 1F
32 F
____________
____________
100F
____________
____________
200 F
____________
____________
300 F
____________
____________
Transducer: T63 Hardware Name: J23
211