TB 1-4920-443-35
AEDATS IV T64 ALIGNMENT WORKSHEET
(g) PT-103,
0-50 in-h2o, B/M Static Pressure #2
(e) Locate PT-103 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results.
Vertical Scale bottom row 7
5SE01313-19
Actual
AEDATS 4
6SE00950-29
Pressure
Pressure
(PS2)
Vertical Scale
(in-h2o)
psi
+/- .25 psi
+/- .25 psi
0
____________
____________ ____________
10
____________
____________ ____________
20
____________
____________ ____________
30
____________
____________ ____________
40
____________
____________ ____________
50
____________
____________ ____________
R-cal
____________
Transducer: T38 Hardware Name: HL19
(h) PT-104,
0-50 in-h2o, B/M Total Pressure
(f) Locate PT-104 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results.
Vertical Scale bottom row 8
5SE01313-19
Actual
AEDATS 4
6SE00950-29
Pressure
Pressure
(PT1)
Vertical Scale
(in-h2o)
psi
+/- .25 psi
+/- .25 psi
0
____________
____________ ____________
10
____________
____________ ____________
20
____________
____________ ____________
30
____________
____________ ____________
40
____________
____________ ____________
50
____________
____________ ____________
R-cal
____________
Transducer: T39 Hardware Name: HL20
(11)Temperature measurement system:
(Refer to page 27 step 29) (AN 6520 Temp Calibrator)
(a) Low temperature channels
(b) Channel 11
P-801
Engine Oil inlet Temp (Spare)
Input
Doric
AEDATS 4
+/- 2F
(Toil_in )
+/- 1F
32 F
____________
____________
100 F
____________
____________
200 F
____________
____________
300 F
____________
____________
Transducer: T19 Hardware Name: J12
207