TB 1-4920-443-35
AEDATS IV T64 ALIGNMENT WORKSHEET
(k) Channel 26 TC 209
Fuel tank (TC208 Same as Hydrometer Temp)
Input
Doric
AEDATS 4
+/- 2F
(TfuelT )
+/- 1F
32 F ____________ ____________
100F ____________ ____________
200 F ____________ ____________
300 F ____________ ____________
Transducer: T66 Hardware Name: J26
Channel 21
J20
Dyno Dyno lube inlet temp (Refer to
page 32 step 34)
(l)
Input
Doric
AEDATS 4
+/- 2F
(Tdyn_Tnk)
+/- 1F
32 F
____________
____________
100F
____________
____________
150 F
____________
____________
175 F
____________
____________
200F
____________
____________
300F
____________
____________
Transducer: T61 Hardware Name: J21
(m) Temperature and Speed Limit Control Panel (Refer to page 35 step 38)
1 Dyno-Lube Inlet Temperature, J20 Thumb wheel setting 200
Input
Calibrator
Limit Control Panel
Indicator lit
Temp F
+/- 3F
+/- 3F
32 F
____________
____________
In limit
100 F
____________
____________
In limit
150 F
____________
____________
In limit
180 F
____________
____________
90% Alert
____________
200 F
____________
____________
100% Warning
____________
210