TB 1-4920-443-35
(7) MT8:
-15 to +5 PSIG (T64)
Using the pressure calibrator, apply the following pressures to MT8 for T64 and record results.
Table 43-7 MT8 Alignment
Target
Calibrator
Vertical Scale
AEDATS
Pressure (psig)
Pressure (psig)
Top Row #8
PTsump ( 1 PSI)
Indicator ( 1.0 PSI)
See Note below
-15
-10
-5
vent
5
RCAL=
NOTE
AEDATS channel name is PTsump for T64 engines only.
AEDATS Alignment MT8 - See Calibration of Automatic Data Acquisition H345-1
(AEDATS II), or H355-7 (AEDATS IV) for FEDS Alignment requirements.
(8) MT9:
0-100 PSIG (T53, T55, T63, 714A & 64)
Using the pressure calibrator, apply the following pressures to MT9 for T53 and record the results.
Table 43-8 MT9 T53 Alignment
Target
Calibrator
Vertical Scale
AEDATS
Pressure (psig)
Pressure (psig)
Top Row #9
( 1.0 PSI)
Indicator ( 1.0 PSI)
See Note below
VENT
20
40
60
80
100
RCAL=
NOTE
For AEDATS II Channel names, refer to AEDATS (H345-1) Technical Manual, Appendix C and
for AEDATS IV Channel names, refer to AEDATS (H355-7) Technical Manual. Chapter 6.
AEDATS Alignment MT9 - See Calibration of Automatic Data Acquisition H345-1
(AEDATS II), or H355-7 (AEDATS IV) for FEDS Alignment requirements.