TB 1-4920-443-35
AEDATS IV T700 ALIGNMENT WORKSHEET
(k) Channel 30, P-104, INLET AIR TEMP (Refer to
page 24 step 28)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(T28)
+/- 1F
32 F
____________
____________
____________
70 F
____________
____________
____________
100 F
____________
____________
____________
120 F
____________
____________
____________
Transducer: T54
Hardware Name: J14
(l) Channel 7, J20 Dyno Oil Tank (Refer to
page 24 step 28)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(Tdyn_tnk)
+/- 1F
32 F
____________
____________
____________
100 F
____________
____________
____________
200 F
____________
____________
____________
300 F
____________
____________
____________
Transducer: T15
Hardware Name: J08
(m) Temperature and Speed Limit Control Panel (Refer to
page 35 step 37)
1 Dyno-Lube Inlet Temperature, J20 Thumb wheel setting 200
Input
Calibrator
Limit Control Panel
Indicator lit
Temp F
+/- 3F
32 F
____________
____________
In limit
100 F
____________
____________
In limit
150 F
____________
____________
In limit
180 F
____________
____________
90% Alert
____________
200 F
____________
____________
100% Warning
____________
161