TB 1-4920-443-35
AEDATS IV T700 ALIGNMENT WORKSHEET
(10)High temperature system, TGT
(a) THERMOCOUPLE TYPE K
(b) Channel 1, E1 Cable Pins 17 {+}(yellow) 16 {-}(red)
Input
Calibrator
Doric
AEDATS 4
Analog
Digital
Temp F
+/- 2
+/- 2
+/- 2
(TGT)
+/- 1
400F
____________
____________
____________
____________
____________
800F
____________
____________
____________
____________
____________
1200F
____________
____________
____________
____________
____________
1650F
____________
____________
____________
____________
____________
2000F
____________
____________
____________
____________
____________
Transducer: T3
Hardware Name: K01
NOTE 1: Analog gauge adjustments are as follow:
1
R6 for digital at 100F
2
R12 for analog at 100F
3
R15 for digital at 1000F
4
R21 for analog at 1000F
5
NOTE 2: perform the above adjustments if the instrument is out of tolerance.
6
(11)Vibration system (Vibration Test # 1)
(a) Set variable filter channel switches to 1, filter selector switch to out.
(b) Set all meters as follows:
1 Filter switch to
CAL
2 Range switch to
150
3 Xducer switch to
ACC
4 Mode switch to
VEL
5 Output switch to
AVG
(c) Adjust Cal pot to (105) on digital display on all channels
(d) Set filter switch to sensitivity and adjust Sens pot for an indication of 150 on all channels
(e) Reset:
1 Output switches to
AVG
2 Mode switches to
VEL
3 Range switches to
5.0
4 Filter switches to
OUT
5 Xducer switches to
VEL
(f) Jumper across pins as listed on step J and adjust R4 for zero (CEC 4000-1010)
(g) After zeroing indicators, go back to step B through E and recheck CAL and SENS settings
(h) Connect test oscillator to
the following connectors:
Plug
Pins
Ground
Channel
P-25
L-C
C
1
P-25
B-E
E
2
P-25
M-G
G
3
P-91
N-G
G
4
P-91
B-M
M
5
163