TB 1-4920-443-35
AEDATS IV T700 ALIGNMENT WORKSHEET
(n) Dyno-lube delta temperature (Refer to page 35 step 38)
1 Calibrator J23 Jumper J20, Thumb wheel setting 80
2 Disconnect J24
Input
Calibrator
Limit Control Panel
ADATS 4
Temp F
+/- 3F
(TDyn_FA)
+/- 1F
32 F
____________
____________
100 F
____________
____________
200 F
____________
____________
300 F
____________
____________
ambient +74F
____________
____________
90% Alert
____________
Ambient +80F
____________
____________
100% Warning
____________
Audible warning
____________
Transducer: T18
Hardware Name: J11
(o) Channel 8, J21 Dyno oil Forward (LINE R/S DYNO)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(Tdyn_fwd)
+/- 1F
32 F
____________
____________
____________
100 F
____________
____________
____________
200 F
____________
____________
____________
300 F
____________
____________
____________
Transducer: T16
Hardware Name: J09
(p) Channel 9, J22 Dyno Oil Aft (REAR OF DYNO)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(Tdyn_aft)
+/- 1F
32 F
____________
____________
____________
100 F
____________
____________
____________
200 F
____________
____________
____________
300 F
____________
____________
____________
Transducer: T17
Hardware Name: J10
162