TB 1-4920-443-35
AEDATS IV T700 ALIGNMENT WORKSHEET
(8) Low Temperature Measurement System
NOTE
If adjustment on the Doric is needed, remove the two screws from the side of the
front panel and remove the panel. The two potentiometers are visible at the upper
left of the display. R44 (Front Panel ZERO) potentiometer controls the 32 reference
and R45 (SPAN) potentiometer controls the positive (+) full scale (1000) Adjust the
thermocouple calibrator to 300 and the Doric display should be 300 +/- 1, if not,
repeat adjustment.
(a) Low Temperature Channels (Use shorting connector to obtain ambient temperature)
(b) Channel 1 P-56 Engine Oil Discharge (Refer to
page 25 step 27
9a)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(EODT)
+/- 1F
32 F
____________
____________
____________
100 F
____________
____________
____________
200 F
____________
____________
____________
300 F
____________
____________
____________
Transducer: T10
Hardware Name: J02
(9) Temperature and Speed Limit Control Panel
(a) Engine Discharge Temperature
P-56
Thumb wheel setting 300
Input
Calibrator
Limit Control Panel
Indicator lit
Temp F
+/- 3F
32 F
____________
____________
In limit
100 F
____________
____________
In limit
200 F
____________
____________
In limit
270 F
____________
____________
90% Alert
____________
300 F
____________
____________
100% Warning
____________
(b) Channel 2, P-57 Eng. Oil Scav. Temp. (Refer to
page 25 step 28)
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(BSUMP)
+/- 1F
32 F
____________
____________
____________
100 F
____________
____________
____________
200 F
____________
____________
____________
300 F
____________
____________
____________
Transducer: T113
Hardware Name: J03
158