TB 1-4920-443-35
AEDATS IV T700 ALIGNMENT WORKSHEET
(c) Temperature and Speed Limit Control Panel (Refer to page 33 step 37)
1 Engine oil delta temperature P-57 Jumper P-56 Thumb wheel setting 150
Input
Calibrator
Limit Control
Indicator lit
Temp F
Panel
+/- 3F
Ambient
____________
____________
90% Alert
____________
+135F
Ambient
____________
____________
100%
____________
+150F
Warning
Audible
____________
____________
warning
(d) Channel 3, P-58 INLET AIR TEMP
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(T21)
+/- 1F
32 F
____________
____________
____________
70 F
____________
____________
____________
100 F
____________
____________
____________
120 F
____________
____________
____________
Transducer: T11
Hardware Name: J04
(e) Channel 4, P-59 INLET AIR TEMP
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(T22)
+/- 1F
32 F
____________
____________
____________
70 F
____________
____________
____________
100 F
____________
____________
____________
120 F
____________
____________
____________
Transducer: T12
Hardware Name: J05
(f) Channel 5, P-68, INLET AIR TEMP
Input
Calibrator
Doric
AEDATS 4
Temp F
+/- 1F
(T23)
+/- 1F
32 F
____________
____________
____________
70 F
____________
____________
____________
100 F
____________
____________
____________
120 F
____________
____________
____________
Transducer: T13
Hardware Name: J02
159