TB 1-4920-443-35
Table 29-2
Channel Name
DORIC
AEDATS
Calibrator
DORIC and AEDATS
DORIC
AEDATS
Connector
Channel
Channel
Temp (F)
Tolerance Limits (1)
Reading
Reading
32
31 to 33
* Eng oil inlet
100
99 to 101
P801
11
Toil_in
temp T53/ 63/T64
200
199 to 201
(Step 35)
300
299 to 301
31 to 33
32
* Eng oil out temp
100
99 to 101
P802
12
Toil_out
T53/T63/T64 (Step
200
199 to 201
36)
300
299 to 301
31 to 33
32
Bell mouth Temp
70
69 to 71
P803
13
T22
#1
100
99 to 101
T53/T55/T63/T64
120
119 to 121
31 to 33
32
Bell mouth Temp
70
69 to 71
P804
14
Tt12
#2
100
99 to 101
T53/T55/T63/T64
120
119 to 121
31 to 33
32
T64 Bell mouth 3
200
199 - 201
Combustor Disch.
P805
15
CDT
400
399 - 401
Temp T53/T55
600
599 601
T63/TA12
800
799 - 801
T64 Bell mouth 4
31 to 33
32
Bell mouth Temp
70
69 to 71
P806
16
Twf
#3 T53/T55
100
99 to 101
T63/TWFFuel
120
119 to 121
Temp Thermo
31 to 33
32
Combustor Disch
200
199 - 201
P807
17
T32
Temp T53 T55
400
399 - 401
TPTS0 T63 TA12
600
599 601
800
799 - 801
31 to 33
32
P.T. Bearing
200
199 - 201
P808
18
Tptso
Scavenge T53 T55
400
399 - 401
T2BS0 T63 TRef1
600
599 601
800
799 - 801
31 to 33
32
#2 Bearing
200
199 - 201
Scavenge T53 T63
P809
19
T2bso
400
399 - 401
TRef2 T64 Oil Tnk
600
599 601
T55 Comb. Static
800
799 - 801