TM 5-6675-316-14
NOTE
Plastic plates for glass supports must be installed with numbers corres-
ponding to numbers on frame.
cq.
Install plastic plates on glass supports.
CAUTION
Glass top is fragile and can be easily broken. Handle with care and do
not allow glass to hit machine frame.
NOTE
Three personnel are required to install glass onto frame. Two personnel
to carry and position glass and a third person to support glass from be-
neath table frame as it is lowered onto supports.
cr.
Install digitizer keyboard stand to left front of table. Secure with
two capscrews.
cs.
Position digitizer keyboard on keyboard stand.
ct.
Reinstall wooden panel.
cu.
Install card cage underneath table frame with socket head capscrews.
cv.
Connect three wires as marked to capacitor located on side of cage.
cw.
Install ribbon cable connector to left side of frame.
cx.
cy.
cz.
da.
db .
dc.
dd.
de.
df.
dg.
3-196
Connect ribbon cable harness to card cage and connector.
Reconnect wiring to card cage.
Remove socket head capscrews from Y-rail end plate at front end.
Remove plate.
Remove socket head capscrews from rubber stop at front end of Y-rail.
Remove stop.
Remove socket head capscrews from Y-carriage tensioning device.
Remove tensioning device.
Move Y-carriage motor locking lever to right.
Slide motor mount to right.