TM 5-3610-286-10
2-7.
OPERATING PROCEDURES (CONT)
i.
Drain Dampening Assembly (Cont)
(1) Turn off dampening fountain continuous flow valve (1).
(2) Insert plastic tubing over dampening fountain drain nozzle (2).
(3) Open dampening fountain drain valve (3) and drain old solution
into container.
(4) Flush dampening fountain (4) with clean water.
(5) Dry dampening fountain (4) with clean rag.
(6) Polish all chrome rollers.
(7) Perform after operation PMCS (table 2-1).
2-104