TM 5-3610-253-14
Remove bolts and P2 block.
g.
h. Remove bolts and valve M1.
Remove bolts and valve M2.
i.
Remove bolts and defective control block from clamp cylinder. Do not
j.
retain O-rings.
k. Remove pipes from defective control block and reinstall on new block.
Use new copper washers.
Using new O-rings, install new control block onto clamp cylinder.
l.
Using new O-rings, reinstall valve M2.
m.
Using new O-rings, reinstall valve M1.
n.
Using new O-rings, reinstall P2 block.
o.
Using new O-rings, reinstall P1 block.
p.
Reconnect electrical connectors.
q.
r.
MOS:
83FJ6, Reproduction Equipment Repairer
Flat Tip Screwdriver
TOOLS:
8 mm Hex Head Socket Bit with 3/8 in. Drive
13 mm Socket with 3/8 in. Drive
12 mm Hex Head Socket Bit with 1/2 in. Drive
10 mm Combination Wrench
22 mm Combination Wrench
Fluid Evacuation Pump
Crow Bar
Clamp Cylinder
SUPPLIES:
O-Rings
Copper Washers
Clamp Base Spacers
Small 2 x 4 Block of Wood
Pail
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
5-551