TM 5-3610-253-14
NOTE
Before tightening the clamp hydraulic cylinder to inner wall of the
hydraulic reservoir, reinstall hydraulic cylinder and main drive gear
clutch connecting pipe.
t.
Install new cylinder into pillar and seat it onto pedestal.
Reinstall alinement pin.
u.
If mounting holes do not aline with bolt holes, remove cylinder and
v.
insert spacers under pedestal and repeat steps t. and v. until holes
aline.
NOTE
When reinstalling the piping for the clamp hydraulic cylinder, it will
be necessary to loosen the hydraulic pump mounting plate to fit the
pipe properly.
w.
Reinstall clamp cylinder mounting bolts and tighten.
Reinstall piston cover plate mounting bolts and tighten.
x.
Reinstall plastic splash ring around clamp piston.
y.
Using crow bar, raise clamp and remove block of wood.
z.
Reconnect all pipes to clamp cylinder.
aa.
ab.
Reinstall control block and secure with mounting bolts.
Reconnect all pipes to control block.
ac.
Reconnect electrical plug connectors.
ad.
ae.
Reinstall access cover above hydraulic pump.
Reinstall main motor V-belt cover.
af.
ag.
Fill hydraulic reservoir with 17 liters (4.5 gallons) of hydraulic
fluid. Observe sight glass for exact quantity required.
ah.
5-556