TM 5-3610-253-14
NOTE
Always use new O-rings.
Install new O-rings and new valve and secure with mounting bolts.
g.
Reconnect plug connectors.
h.
i.
83FJ6, Reproduction Equipment Repairer
MOS:
TOOLS: Flat Tip Screwdriver
13 mm Combination Wrench
27 mm Combination Wrench
22 mm Combination Wrench
Fluid Evacuating Pump
SUPPLIES: Inch Valve
Pail
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
Turn off power.
a.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. Remove front electronics enclosure cover.
Remove right pillar cover.
c.
d. Remove hydraulic system cover plate.
NOTE
If hydraulic fluid is to be reused, be sure pail is clean before placing
fluid into it.
Using fluid evacuating pump, remove all hydraulic fluid from reservoir.
e.
5-547